Usually found where the cold air enters the unit either in the cold air return duct or the entrance to the blower chamber.
Carrier furnace inducer motor fault.
Status code 42 inducer motor fault step action go to does the voltage fluctuate as described in step 28.
Draft inducer motor failure.
Thirty seconds after being turned on or ten.
Locate the current filter.
Part number part description part link 20054001 carrier 20054001 draft inducer motor assembly view carrier part 20054001 2272065 carrier 2272065 draft inducer motor assembly view carrier part 2272065 2272158 carrier 2272158 draft inducer motor assembly view carrier part 2272158 308088 751 carrier 308088 751 draft inducer housing view carrier part 308088 751 308118 405 carrier.
Added to ensure heating systems are able to comply with the most recent government mandated efficiency standards it is designed to facilitate the removal of gases and air from the furnace and out to the chimney.
Fault code 11 means the inducer motor is functioning properly.
The draft inducer blower is a relatively new component found on modern furnace units.
These tubes are the small one coming off the firebox and motor housing going to a drain.
Bad capacitor causing motor not to start up.
From the carrier 58mvp service manual.
Leak in tubing defective pressure switch restricted vent bad inducer motor rule out motor it works if the tube off the induced draft blower housing are plugged it will cause this trip.
Open the door panel to get access to your carrier furnace.
Blower motor fault indicates the blower failed to reach 250 rpm or the blower failed to communicate within the prescribed time limits.
Take out the old air filter and replace it with a new one.
One common issue with any blower motor in hvac systems is a bad capacitor.
Fault code 42 means inducer outside valid speed range this indicates that 10 seconds have elapsed and the inducer motor has not started or the inducer motor has started but is not operating at expected r p m.